The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
2016 cbc roof covering. For roof pitches below 2 12 a low sloped roofing system approved by the building official shall be used. N forms and handouts 2013 cbc attached patio cover 2013 crc oct 2014 doc page 4 of 5. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process. 2016 california green building standards code california code of regulations title 24 part 11 first printing.
The 2016 update to the building energy efficiency standards focuses on several key areas to improve the energy efficiency of newly constructed buildings and additions and alterations to existing buildings. 707a 3 1 r337 7 3 1 exterior wall coverings shall extend from the top of the foundation to the roof and terminate at 2 inch nominal solid wood blocking between rafters at all roof overhangs or in the case of enclosed eaves terminate at the enclosure. 1507 2 8 2016 crc table 905 1 1 2 2. Structural standing seam metal panel roof systems shall be tested in accordance with astm e1592 or fm 4474.
Allowable spans for df 2 roof rafters dead load 10 psf includes maximum roofing material load 6 psf built up or composition shingle roofing live load 20 psf allowable spans for df 2 ceiling joists dead load 10 psf live load 10 psf. 978 1 60983 659 7 published by international code council 500 new jersey avenue nw 6th floor washington d c. The 2016 california building standards code cal. Information bulletins 16 01 and 17 06 provide detailed information concerning changes to the.
Additionally the intervening supplement was published january 1 2017 with an effective date of july 1 2018. Code regs title 24 was published july 1 2016 with an effective date of january 1 2017. Structural through fastened metal panel roof systems shall be tested in accordance. Plywood or particle board must be cc exterior or better and rated for the span being used.
Where the metal roof panel functions as the roof deck and roof covering and it provides both weather protection and support for loads the structural metal panel roof system shall comply with this section. Nailing shall be a minimum of 8d at 6 o c. The entire building shall be provided with not less than a class b roof covering. 2016 california building code legally binding document.
Addeddate 2016 08 15 18 57 40 identifier gov ca bsc title24 2016 02 1 identifier ark ark 13960 t2s51gw9c ocr abbyy finereader 11 0 extended ocr ppi 300. The most significant efficiency improvements to the residential standards include improvements for attics walls water heating and lighting.